Welcome to our store Learn more

Tripp Lite  |  SKU: DT-037332136428

Tripp Lite 1.4kW Single-Phase ATS / Switched PDU with LX Platform Interface, 120V outlets (8 5-15R), 2 5-15P 120V 12ft Inputs, 1U Rack-Mount, TAA, 2 Year Warranty (PDUMH15ATNET ) Black Switched + ATS PDU

Model Number: PDUMH15ATNET

$616.32 USD
Shipping calculated at checkout.


Delivery and Shipping

Add some general information about your delivery and shipping policies.

Tripp Lite switched ATS/ auto transfer switch provides a redundant power option for single-corded network devices. Dual input cords support separate connection to primary and secondary power sources. The ATS will normally maintain continuous output to all outlets as derived from the primary input cable. If the primary power source becomes unstable or fails altogether, The ATS will switch over to the secondary power source until the primary input is restored and stable. The built-in javan-free HTML5-based LX Platform interface enables full remote access for PDU status monitoring and email notifications via secure web browser, snap, telnet or SSH. It supports 10/100 Mbps auto-sensing for optimum communication with an Ethernet network. Optional envirosense2 modules (sold separately) provide a variety of environmental monitoring capabilities. Protocols supported include IPv4, IPv6, HTTP, HTTPS, SMTP, SNMPv1, SNMPv2, SNMPv3, telnet, SSH, FTP, DHCP, boots and NTP. Switched PDU features include individually controllable output receptacles. Super-fast switchover between primary and secondary power sources occurs within milliseconds. Ats functionality is supported by any two compatible AC power sources, regardless of phase angle, to support a variety of advanced redundant power networking applications. Enables fault tolerant hot-swappable UPS protection when used with a single UPS and fully redundant UPS protection when each cord is connected to a separate UPS system. In a two-up environment, The primary input cable must be supported by a full time sine WAVE ups with zero transfer time. Tripp Lite smart online Series is highly recommended for use as the primary UPS in a two-up application. Ats configurations utilizing separate mains circuits, backup Generators and even separate utility power Grid feeds are fully supported. On-board ATS processor constantly evaluates power quality on both input sources to prevent transfer to the secondary source when unavailable or of lower quality than the primary source. Front input Lad's display primary or secondary power availability.

Payment & Security

Payment methods

  • American Express
  • Apple Pay
  • Diners Club
  • Discover
  • Google Pay
  • Mastercard
  • PayPal
  • Shop Pay
  • Visa

Your payment information is processed securely. We do not store credit card details nor have access to your credit card information.

Customer Reviews

Be the first to write a review
0%
(0)
0%
(0)
0%
(0)
0%
(0)
0%
(0)
Tripp Lite

Tripp Lite 1.4kW Single-Phase ATS / Switched PDU with LX Platform Interface, 120V outlets (8 5-15R), 2 5-15P 120V 12ft Inputs, 1U Rack-Mount, TAA, 2 Year Warranty (PDUMH15ATNET ) Black Switched + ATS PDU

$616.32 USD

Tripp Lite switched ATS/ auto transfer switch provides a redundant power option for single-corded network devices. Dual input cords support separate connection to primary and secondary power sources. The ATS will normally maintain continuous output to all outlets as derived from the primary input cable. If the primary power source becomes unstable or fails altogether, The ATS will switch over to the secondary power source until the primary input is restored and stable. The built-in javan-free HTML5-based LX Platform interface enables full remote access for PDU status monitoring and email notifications via secure web browser, snap, telnet or SSH. It supports 10/100 Mbps auto-sensing for optimum communication with an Ethernet network. Optional envirosense2 modules (sold separately) provide a variety of environmental monitoring capabilities. Protocols supported include IPv4, IPv6, HTTP, HTTPS, SMTP, SNMPv1, SNMPv2, SNMPv3, telnet, SSH, FTP, DHCP, boots and NTP. Switched PDU features include individually controllable output receptacles. Super-fast switchover between primary and secondary power sources occurs within milliseconds. Ats functionality is supported by any two compatible AC power sources, regardless of phase angle, to support a variety of advanced redundant power networking applications. Enables fault tolerant hot-swappable UPS protection when used with a single UPS and fully redundant UPS protection when each cord is connected to a separate UPS system. In a two-up environment, The primary input cable must be supported by a full time sine WAVE ups with zero transfer time. Tripp Lite smart online Series is highly recommended for use as the primary UPS in a two-up application. Ats configurations utilizing separate mains circuits, backup Generators and even separate utility power Grid feeds are fully supported. On-board ATS processor constantly evaluates power quality on both input sources to prevent transfer to the secondary source when unavailable or of lower quality than the primary source. Front input Lad's display primary or secondary power availability.

View product